Dynisco logo Industry leader in polymer testing · USA

Precision polymer testing solutions

High-performance MFI testers, capillary rheometers, IV analysis and process-control sensors. Trusted by polymer leaders worldwide for accuracy and reliability. Supplied, installed and serviced across India by FITCO.

50+
Years
±0.1°C
Precision
±0.5%
Accuracy
1000+
Installations
Dynisco LMI 5500 Melt Flow Indexer
Trusted by

Industry leaders worldwide

DuPont
Reliance
Ineos Styrolution
Avient
Celanese
EREMA
Starlinger
Foxconn
Chemco
Chiripal
RiBotl

Top recyclers across India use the Dynisco LMI 5500 for Intrinsic Viscosity (IV) testing of PET & rPET materials.

See it in action

Equipment demonstrations

Watch Dynisco polymer testing equipment deliver precision and reliability.

Automatic MFI Testing
Automatic MFI Testing
1 of 6 videos
Automatic MFI Testing
Automatic MFI Testing
IV PET Analysis
IV PET Analysis
OTR Permeation Testing
OTR Permeation Testing
WVTR Moisture Testing
WVTR Moisture Testing
Wabash Press Demo
Wabash Press Demo
Pneumatic Press
Pneumatic Press
Technical specifications

Detailed product insights

Comprehensive specifications for our precision testing equipment.

LMI 5500 Series Melt Flow Indexer

High-precision MFI/MVR testing with ±0.1°C temperature control.
ASTM D1238 · ISO 1133
Primary standard ASTM D1238
ISO compliance ISO 1133-1/2
Temperature precision ±0.1°C
MFR range 0.1–50 g/10min
Accuracy ±0.5%
Cut modes Auto / Manual
Connectivity USB & LAN
Interface LCD touchscreen
Maintenance Auto-clean
Advanced MFI testing

±0.1°C stability for accurate melt-flow-rate measurements.

Comprehensive standards

Procedures A, B, C and D per ASTM D1238 and ISO 1133.

User-friendly operation

Intuitive touchscreen with automatic test parameters.

LCR 7000 Series Capillary Rheometer

Complete polymer characterisation with multi-bore testing.
ASTM D3835 · ISO 11443
Primary standard ASTM D3835
ISO compliance ISO 11443
Temperature range 25–400°C
Shear rate 0.001–5000 1/s
Max pressure 30,000 psi
Capillary Multi-bore (Bagley)
Data PVT measurements
Piston speed 1–50 mm/min
Capillary dia. 0.5–3.0 mm
Advanced rheological analysis

Precise viscosity measurement for full characterisation.

Multi-functional testing

Capillary rheometry, PVT and extensional viscosity in one.

Superior data acquisition

High-resolution transducers, D3835 / ISO 11443 compliant.

ViscoIndicator & process sensors

Real-time process monitoring with Industry 4.0 connectivity.
Process sensors · Industry 4.0
Pressure range 0–30,000 psi
Accuracy ±0.5% FS
Temperature range up to 400°C
Output signal 0.01–10 VDC
Sensing tech NaK-filled
Connectivity Industry 4.0
Display Digital
Certification Hazardous-area
Real-time monitoring

Continuous extrusion and injection-moulding monitoring.

Superior durability

NaK-filled sensing for long life in harsh environments.

Integrated solutions

Complete systems with seamless plant integration.

Technical capabilities

Standards compliance

Certified testing protocols for global acceptance.

ASTM D1238 & ISO 1133 — MFI testing

Complete compliance with international melt-flow-rate standards. Procedures A, B, C and D with automatic calculation and documentation.

  • Temperature range 50–400°C with ±0.1°C stability
  • Weight sets 0.325 kg to 21.6 kg (ASTM/ISO compliant)
  • Automatic/manual cutting modes with timing precision
  • MVR and MFR measurement with density calculation

ASTM D3835 — rheological analysis

Pressure-driven capillary viscometry for viscosity curves, shear sensitivity and thermal-stability analysis.

  • Shear-rate range 0.001 to 5000 s⁻¹
  • Pressure capability up to 30,000 psi
  • Multi-bore capillary testing for Bagley correction
  • PVT measurements for density vs. temperature
Critical applications

Industry-specific testing solutions

Specialised testing protocols for demanding applications.

PET recycling

Intrinsic Viscosity (IV) testing for rPET quality

IV measurement determines molecular weight and degradation. Starlinger and EREMA lines need precise IV control for bottle-grade rPET.

0.70–0.85
IV range (dL/g)
LMI 5500
recommended
Extrusion control

MFI testing for film & sheet production

MFI correlation (2–8 g/10min for LDPE film) ensures consistent melt flow. Real-time testing reduces scrap and holds gauge tolerance.

±0.5%
repeatability
30%
scrap reduction
Material qualification

Incoming raw-material QC testing

Verify supplier consistency before production. Batch-to-batch MFI variation >10% flags material issues early.

10%
variation limit
5 min
test time

"In polymer processing, precision isn't optional — it's survival. We reduced reject rates from 12% to under 2% simply by implementing proper MFI testing protocols. Investing in US-engineered Dynisco equipment delivers 10× ROI through reduced waste, minimised downtime and unmatched accuracy."

Vice President — Quality & Process EngineeringLeading Indian PET preform & masterbatch manufacturer · 25+ years in polymer processing
Technical insights

Did you know?

Critical testing facts that impact your production quality.

A 2°C temperature deviation during MFI testing can cause 15–20% variation in flow-rate readings, leading to incorrect material selection and production failures.

Temperature control matters — ±0.1°C Dynisco vs ±0.5°C industry average

PET bottle manufacturers lose ₹50–80 lakhs annually to improper IV monitoring. Recycled PET below 0.72 dL/g fails bottle production, causing batch rejection.

rPET quality control — critical for Starlinger & EREMA lines

Film lines running 24/7 consume 200–500 kg/hr. A 5% MFI variation means thickness fluctuation and ~30 kg/hr scrap — lakhs in monthly LDPE waste.

Cost of inconsistency — MFI testing pays for itself in 4–6 months
Get started

Transform your polymer testing with industry-leading precision

Join 1000+ manufacturers worldwide who trust Dynisco for critical quality control and R&D. Experience the difference that ±0.1°C control and ±0.5% accuracy makes.

Compliance guaranteed

Full ASTM D1238, ISO 1133, ASTM D3835 and ISO 11443 certification with documentation.

Expert support & training

Installation, calibration and operator training by certified technicians, with ongoing support.

ROI in 6–12 months

Cut scrap by up to 30%, minimise waste and optimise process parameters.

Why choose us now
24–48 hrs
Quote response time
100%
Factory calibrated
2–4 weeks
Delivery timeline
WhatsApp Call Now