Skip to main content
XFS 500kN Universal Testing Machine | Testometric Floor Standing UTM India

500kN XFS Floor Standing Universal Testing Machine

Heavy-duty testing excellence for demanding applications. UK-manufactured high-capacity UTM with AC servo drive technology delivering exceptional performance for rigorous industrial testing.

ISO 7500-1 Class 0.5 Made in UK ±0.5% Accuracy
XFS 500kN Floor Standing UTM
Why Choose XFS 500kN

Heavy-Duty Capacity with Laboratory Precision

Engineered for demanding industrial applications, the XFS 500kN combines robust capacity with world-class accuracy for comprehensive heavy-duty materials testing.

500kN Heavy-Duty Capacity

Exceptional 500kN load capacity with ±0.5% accuracy conforming to BS EN ISO 7500-1 Class 0.5. Engineered for demanding industrial testing requiring both power and precision.

Industrial AC Servo Drive

High-torque servo motor system with precision ball screw delivers exceptional force control and positioning accuracy. Built for continuous operation in demanding production environments.

WinTest Advanced Analysis

Professional-grade Windows software with advanced data analysis, customizable test protocols, automated reporting, and comprehensive statistical tools for quality assurance.

Reinforced Frame Structure

Heavy-duty reinforced steel construction with maximum rigidity for superior stability under high loads. Premium powder-coated finish ensures longevity in harsh industrial settings.

Maximum Testing Flexibility

Ultra-wide speed range (0.001-1000 mm/min) with 1200mm test space accommodates extensive testing requirements from ultra-slow creep to high-speed dynamic tests.

British Manufacturing Heritage

Proudly manufactured in the UK with Testometric's legendary quality standards. Over 50 years of engineering excellence delivering world-class testing solutions globally.

Technical Data

Complete Technical Specifications

Detailed specifications for the XFS 500kN Floor Standing Universal Testing Machine

Maximum Load Capacity
500 kN
Load Cell Accuracy
±0.5% (Class 0.5)
Test Space
1200 mm
Crosshead Speed Range
0.001-1000 mm/min
Position Accuracy
±0.01 mm
Frame Width
680 mm
Specification Value
Maximum Load Capacity 500 kN
Load Cell Accuracy ±0.5% of indicated load down to 1/500 of load cell capacity (BS EN ISO 7500-1 Class 0.5)
Load Cell Specification ±1% of indicated load down to 1/250 of load cell capacity (BS EN ISO 7500-1 Class 1.0)
Load Resolution 1/500,000 of load cell capacity
Test Space (Height) 1200 mm
Frame Width 680 mm (internal)
Crosshead Speed Range 0.001 to 1000 mm/min (infinitely variable)
Position Accuracy ±0.01 mm
Crosshead Return Speed Up to 1000 mm/min
Drive System AC Servo motor with precision ball screw
Overall Height 2650 mm
Overall Width 750 mm
Overall Depth 650 mm
Machine Weight Approximately 850 kg
Power Supply 230V AC, 50/60Hz, Single Phase
Software WinTest Analysis Suite (Windows-based)
Data Output USB, Ethernet connectivity
Compliance Standards ISO 7500-1, ASTM E4, BS 1610, DIN 51221
Industry Applications

Versatile Heavy-Duty Testing Solutions

The XFS 500kN UTM excels in demanding heavy-duty industrial testing applications

Structural Composites

Heavy Metals Testing

Reinforced Textiles

Industrial Components

Aerospace Structures

Steel Fabrication

Engineered Wood

Heavy-Duty QC

Industrial R&D

Defense Materials

Structural Elements

Heavy Vehicle Parts

Risk Intelligence

The Cost of Inadequate Testing

Why leading aerospace, automotive, and industrial labs specify Testometric for mission-critical applications

A 1% error in tensile test results for aerospace composites can invalidate entire batch certifications. ASTM E4 Class 0.5 accuracy (±0.5% of reading) is the minimum for structural components—anything less risks regulatory rejection.

Accuracy Standards Matter

Testometric Class 0.5 vs Industry Average Class 1

Medical device manufacturers lose ₹80 lakhs-₹2 crores annually due to failed FDA audits from inadequate tensile testing. Suture and catheter failures traced to ±2% test equipment accuracy—Testometric's ±0.5% prevents these costly rejections.

Medical Device Compliance

Critical for ISO 10555 and ASTM F88 Approval

Automotive seat belt webbing requires 24.5kN minimum breaking strength. A UTM with insufficient rigidity can show 26kN when actual strength is 23kN—resulting in recalls costing ₹50-100 crores. Testometric's dual-column design eliminates frame deflection.

Frame Rigidity = Safety

ROI: Preventing a Single Recall Pays for 10 UTMs

Success Stories

Real Results from Real Customers

See how leading organizations achieved measurable improvements with Testometric

Aerospace

Composite Testing Lab

Major aerospace supplier needed to increase composite testing throughput while maintaining NADCAP certification requirements.

40% Faster test cycles
100% First-time audit pass
X500 Heavy-Duty Benchtop UTM
Medical Device

Catheter Manufacturer

FDA-regulated manufacturer required 21 CFR Part 11 compliant testing with full electronic records and audit trails.

Zero FDA 483 observations
60% Reduced documentation time
X250 Light-Duty with winTest™
Geotechnical

Geosynthetics Testing Laboratory

Civil engineering lab required high-capacity testing for geogrid and geotextile materials with precise elongation measurement and automated data logging.

300+ Tests per week capacity
98% Uptime achieved
XFS 300kN Floor Standing

"Test equipment accuracy directly impacts production certification. When international auditors and OEMs review your data, precision testing systems eliminate questions and delays."

Quality Assurance & Regulatory Compliance

AS9100D Certified Aerospace Component Manufacturer | Tier-1 Global Supplier

18+ Years in Aerospace Materials Testing

Technical Questions

How does the XFS 500kN compare to Instron 5980 series?

Both systems meet ISO 7500-1 Class 0.5 standards. The XFS 500kN uses AC servo drive technology and offers comparable accuracy at 0.5%. Key difference is UK manufacturing heritage since 1970 versus US production. Indian manufacturers typically report lower service costs with UK systems due to established regional support infrastructure.

What distinguishes Testometric from Zwick Roell testing machines?

Testometric and Zwick Roell both manufacture in Europe with similar accuracy specifications. The XFS series uses AC servo drives; Zwick systems vary by model. Both meet international calibration standards. Decision typically depends on existing lab infrastructure and regional service partnerships.

Is the XFS 500kN suitable for heavy industrial testing?

Yes. ISO 7500-1 Class 0.5 certification meets heavy industrial testing requirements. Used by manufacturers for high-strength materials, structural components, and demanding applications. International standards accept data from properly calibrated ISO-certified systems regardless of manufacturer.

What is the typical calibration cycle for 500kN systems?

Annual calibration per ISO 7500-1 standards. Some manufacturers require six-month intervals for critical applications. Calibration duration is 2-3 days including documentation. Regional accredited calibration labs service Testometric equipment across India.

Ready for Heavy-Duty Testing Excellence?

Contact our specialists to discover how the XFS 500kN can elevate your demanding industrial testing operations.